06/07Pharmaceutical Cold Chain MonitoringGDP Compliant
Temperature records that stand up to inspection
Medicines lose potency silently. Our monitoring system keeps every fridge, room and vehicle inside its range, documents every reading, and turns excursions into a clean, signed record.
- Built for GDP
- Continuous monitoring with alarms
- Calibrated probes
- Traceable calibration certificates
- Tamper-evident
- Every action is logged and signed
- Audit-ready
- Reports exported in minutes
Compliance by design
Mapped to what inspectors look for
The system is designed around the EU Guidelines on Good Distribution Practice of medicinal products for human use (2013/C 343/01) and the data-integrity expectations that come with them.
| GDP expectation | How the system meets it |
|---|---|
| Continuous monitoring | Readings logged at short intervals, 24/7, for every storage area and fridge — with local buffering, so a network outage never creates a gap. |
| Calibrated equipment | Probes supplied with traceable calibration certificates; recalibration dates tracked and reminded automatically. |
| Alarm systems | Configurable alarm bands, delays and escalation chains over SMS, email and phone — tested and logged. |
| Records & data integrity | Tamper-evident audit trail, user access control and electronic signatures, following ALCOA+ principles. |
| Temperature mapping | Multi-probe deployments support mapping studies of rooms, cold rooms and fridges. |
| Excursion management | Every excursion captures duration, peak, mean kinetic temperature and the corrective action taken. |
In the field
From the rack to the loading dock
Calibrated probes follow temperature-mapping results: at the hot and cold spots of the racking, inside every medicines fridge and at the dock, where most excursions start.
Mapped rack positions
Probes placed at the warmest and coldest points found in the temperature mapping study.
Calibrated · traceableMedicines fridge
Continuous 2–8 °C monitoring with a local display and an independent probe.
2–8 °CCompliance gateway
Tamper-evident records, electronic signatures and an audit trail for every reading.
Audit trailDock & staging
Loggers travel with the pallet, so time out of storage is captured too.
Handover records
How it works
From excursion to closed record
When something goes wrong, the system guides your team through a documented response — and keeps the evidence.
01
Detect
The probe reading leaves its 2–8 °C or 15–25 °C band.
02
Alert
Responsible people are notified and escalated until acknowledged.
03
Acknowledge
The user records the cause and action, with an electronic signature.
04
Assess
Duration, peak and MKT support the QA decision on stock impact.
05
Close
A sealed incident report is added to the audit trail.
Edge reliability
No gaps in the record — even offline
Compliance fails on missing data. Each device stores readings locally, keeps alarming on its own and back-fills the central record as soon as the connection returns.
If it isn’t recorded, it didn’t happen. So we record it twice: on the device and in the platform.
- Ranges
- 2–8 °C, 15–25 °C, frozen and ultra-lowCustom bands per product and location
- Storage
- On-device memory with back-fillData synchronised when connectivity returns
- Power
- Battery backupMonitoring and alarms continue in a power cut
- Connectivity
- Wi-Fi, Ethernet or 4GAutomatic failover between networks
- Reports
- Daily, monthly and incident reportsPDF and CSV exports for QA and inspectors
Where it’s used
Wherever medicines are stored or moved
Talk to our team
Get ready for your next inspection
Tell us about your sites, storage ranges and QA process. We’ll propose a monitoring set-up and a validation plan that fits them.